Small company. Big projects. Deep expertise.
Rosmarus Enviro's staff have decades of experience gained from complex environmental projects in Sweden and around the world. We know how to lead demanding projects for multinational clients.
We are the sole certified importer, distributor and installer of Solinst FLUTe products in the Nordic countries and continental Europe.

FLUTe Liners: the technology behind the results
FLUTe stands for Flexible Liner Underground Technologies. Since the mid-1990s, FLUTe Technologies (now Solinst FLUTe) has supplied the products better known as FLUTe Liners. FLUTe Liners are used to locate, identify and quantify chlorinated aliphatics in fractured bedrock.
Detect DNAPL and chlorinated solvents in fractured bedrock on site and in time, not afterwards
Solinst FLUTe Liners are still a relatively unknown technology in Europe, but have had a major impact, especially in Sweden. FLUTe Liners have been used in several larger projects to delineate the spread of tetrachloroethene (PCE) and trichloroethene (TCE), both at depth and laterally in the bedrock, before a remediation method is chosen. Few techniques offer the same certainty in identifying free-phase chlorinated solvents in fractures at depth.
FLUTe Liners shorten the time between suspicion and actual documentation of free-phase PCE or TCE. Is it dissolved in the groundwater in open fracture systems, and if so, to what depth? Faster delineation leaves more time and budget for more effective planning of remedial action. Delineate the spread laterally and vertically before procurement and reduce the margins of error.
Instead of leaving a borehole open and risking spread of contamination at depth, or sealing it with concrete after the investigations are finished, the hole can be secured with a Carrier Liner. This keeps the borehole available for a long time for further investigations. Hoist the liner, carry out the work and reinstall it.
Traditional Sonic or diamond-drilled core
Do you use cored rock samples to test whether free-phase solvent is present in the bedrock? The solvent can be washed out of the fractures in the core sample by the cooling water, or evaporate due to frictional heat, before the core reaches the surface. You then risk drawing incorrect conclusions about how contaminated the bedrock is.
FLUTe Liners
Free-phase solvent in the bedrock is identified visually on the NAPL FLUTe liner at the depth where it occurs. Nothing is washed away and nothing has time to evaporate.
Five steps from borehole to clear answer
-
A sealed liner in the borehole
A strong but flexible vinyl liner is installed in the drilled bedrock hole. It seals tightly against the borehole wall and prevents groundwater from flowing in and out of open fractures in the borehole.
-
The NAPL FLUTe membrane shows where the contamination is
Free-phase solvent: The NAPL FLUTe membrane reacts with multicoloured blooms where it has come into contact with free-phase solvent (DNAPL), that is PCE or TCE, or as a streak if it has run down a fracture plane and around the liner in the borehole. The contamination can be identified directly by eye after the liner has been hoisted out of the borehole.
Dissolved in groundwater: the solvent is absorbed by a FACT filter strip (FLUTe Activated Carbon Technology) with micro-granular activated carbon, sewn into a Mylar pocket along the NAPL FLUTe membrane. The strip is analysed by a laboratory and gives a qualitative profile of the solvent distribution and its degradation products in the bedrock along the borehole.
-
Installation with exact depth control
The liner arrives on a reel and is installed by being everted (turned inside out) as it is lowered into the borehole. With this technique, each point of a NAPL FLUTe membrane is in direct contact with the bedrock surface in one location only, which ensures that the exact depth at which the contamination occurred is identified and can be accurately measured.
-
Held in place by water pressure
The liner is held in place by keeping the water level inside the liner 2.5–3 metres (approximately 8 to 10 feet) higher than the standing groundwater level in the open rock borehole, which gives a good hydraulic overpressure. This overpressure forces the flexible vinyl liner against the borehole walls so that it seals tightly against the rock surface. Water and contamination therefore cannot escape through fractures and spread further up or down.
-
Built for tough bedrock
The liner material is available in different designs and material thicknesses. A FLUTe Carrier Liner seals your boreholes. Do not risk causing a larger and deeper spread of contaminated groundwater. Where there is a risk of damage from fractured rock or sharp flint in limestone, we can make the liner in extra heavy-duty vinyl.
Many years of experience with FLUTe Liners
Rosmarus has many years of experience installing and handling FLUTe products.
- We help you prepare the basis for a bedrock investigation, including a budget.
- We prepare the ordering documents according to the work plan.
- We import and deliver to you.
- We install your liners and handle sampling and interpretation of NAPL FLUTe and FACT results.
Rosmarus Enviro was founded by Patrik Nilsson. Patrik holds a PhD in structural geology, has 24 years of experience as an environmental consultant (as of 2026) and is a certified European Geologist (821).
Patrik Nilsson, founder of Rosmarus Enviro
Pontus Nilsson is a senior field technician with many years of experience with FLUTe installations in Sweden and abroad.
Pontus Nilsson, senior field technicianNAPL FLUTe and FACT strip
The reactive NAPL FLUTe membrane shows free-phase solvent, and the FACT strip with activated carbon shows dissolved contamination with depth.
Cased Hole Sampler (CHS)
Level-specific water sampling, with intake ports placed opposite the water-bearing fractures.
Transmissivity and Reverse Head
We carry out transmissivity and Reverse Head profiles using the T-profiler and Carrier Liners.
| Product | Use |
|---|---|
| Carrier Liner | The vinyl liner (Carrier Liner) forms the basis of the system |
| NAPL FLUTe | The reactive NAPL FLUTe membrane for visual identification of free-phase solvent (DNAPL) |
| FACT | The activated-carbon filter strip for dissolved contamination |
| CHS (Cased Hole Sampler) | Level-specific water sampling |
| T-profiling | Transmissivity and Reverse Head profiling |
| DEIL | Discrete Extraction Injection Liner |
| PFAS | Delineation of PFAS at depth with a Carrier Liner, transmissivity profile and Cased Hole Sampler |
A solid basis for decisions
FLUTe Liners give a good picture of the contamination situation in the bedrock when the investigation is properly planned and the liners correctly installed. That is where we can help.
- Choose the right technology for your site
- Determine the number of boreholes needed
- Estimate time and budget for the most suitable investigation
News, conferences and clients
Here you can find where we appear in 2026 and 2027, and some of the clients who trust FLUTe Liners from Rosmarus.
Conferences
- 3–4 MarchATV ExhibitorVejle, Denmark
- 10–12 MarchMUTKU Exhibitor SpeakerFinland
- 18–19 MarchRenare Mark ExhibitorVästerås
- 14–18 September21st ICOM-CC Triennial Conference PosterOslo, Norway
- 15–16 SeptemberNordrocs Exhibitor SpeakerHelsinki, Finland
- 2–3 MarchATV Exhibitor SpeakerVejle, Denmark
- MarchRenare Mark Exhibitor PosterLocation to be announced
- Date to be announcedAquaConSoil ExhibitorLocation to be announced
- 15–16 SeptemberContamination & Land Remediation Expo (CLR)Birmingham, United Kingdom
Some of our clients
Consultants, municipalities, regions and universities in Sweden and Denmark.
Additional services
Environmental and remediation-preparatory investigations
Ground investigations, groundwater, soil gas, surface water and sediment, and telemetric monitoring.
Read more about environmental investigationsGeological investigations
Bedrock mapping, sulphide mineralisation, fracture mapping and geophysical investigations.
Read more about geological investigationsPlanning a bedrock investigation?
Contact us for a discussion about how FLUTe Liners can give you a more reliable result.
patrik@rosmarusenviro.com